Features
- Construction: IC rated for direct contact with insulation for 750lm (6W), 1,000lm (8W), 1,250lm (11W), 1,500lm (14W) outputs. Non IC rated for 2,000lm (19W), 2,500lm (23W), 3,000lm (29W), and 3,500lm (32W) outputs.
Installation: High strength hanger bars can easily be nailed to joists. Suitable for T-grid and drop ceiling applications.
Hanger Bars: Pre-Installed hanger bars with True Nail easy installation in regular lumber, engineered lumber, and laminated beams. Integral T-bar slots for easy installation in T-bars. Spans up to 24" and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while easily aligning the housings with the joists.
Hanger bars ordered separately for Architectural Frame (AF in Product code). 27" Flat bars for wood construction (FB27) and 26" C-Channel bars for T-bar ceiling (CH26) available for purchase.
Electrical: Driver is rated for 120-277V. High Efficiency driver with a power factor > 0.95.
Dimmability: 0-10V/ELV/Triac dimming (1%).
|
|
 |
 |
 |
 |

|