Part Number: EJB4ICDXA
Maximum 2-Hour Fire rated ceiling assembly can be maintained when installed according to Building Code, Section 714.
Dimensions - 4 1/2" H x 5 1/8" W x 8 1/2" L Voltage - 120/277V Finish - Red/Silver
- New Construction IC Airtight Housing for 2-Hour Fire Rated Ceilings
- Compatible with: 4" 0-10V DX Koto Fixtures, 0-10V LED Sky Panels, and 0-10V LED Inserts (EL495 Series)
- Junction Box with hanger bars with quick-connect for easy fixture installation
- Round opening for easy fixture installation
- Optional: ELCO Battery Backup: Sold Separately!
- Covered by U.S. Patents
- Install a Compliant Fixture for CA Title 24 Compliance
- IC Rated for direct contact with insulation
- UL Listed under UL514A Standards as a metallic outlet box
- For 2-Hr Fire rated ceilings
- Maximum 2-hour Fire Rated ceiling assembly can be maintained when installed according to the International Building Code, Section 714
-
-
-
-
-
- Tech Specs
-
| -
-
-
|
-
-
-
| -
-
| -
-
-
| Dimensions | -
| 4 1/2" H x 5 1/8" W x 8 1/2" L | -
-
-
- Construction Type
-
| -
| 0-10V, 120/277V New Construction | -
-
-
| Compatible With | -
| 4" 0-10V DX Koto Fixtures, 0-10V LED Sky Panels, and 4" 0-10V LED Inserts (EL495 series): Sold Separately | -
-
-
| Connection | -
| Quick-Connect | -
-
-
| Included | -
| Junction Box/Hanger Bars/Quick-Connect | -
-
-
- Approval Type
| -
| UL Listed Under UL 514A Standards as a Metallic Outlet Box, For 2-Hour Fire Rated Ceilings, IC Rated for Direct Contact with Insulation | -
-
-
| Other Information | -
| Optional Battery Backup (Fees Apply, Sold Separately) | -
-
-
| Fire Rated | -
| Yes 2-Hour/With International Building Code, Section 714 | -
-
-
| Manufacturer | -
| ELCO Lighting | -
-
-
- Finish
| -
| Red/Silver | -
-
-
-
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
Bulb Type: Trims and Fixtures sold separately, compatible with 4" 0-10V DX Koto Fixtures, 0-10V LED Sky Panels, and 4" 0-10V LED Inserts (EL495series).
Housing ▪ 0-10V, 120/277V New Construction IC Airtight Housing for 2-hour fire rated ceilings. ▪ Round opening for easy hole cutting ▪ Maximum 2-hour Fire Rated ceiling assembly can be maintained when installed according to the international Building Code, Section 714. Covered by U.S. Patents
Installation ▪ Hanger bars can be nailed to joists. ▪ See installation sheet for detailed information.
Hanger Bars Hanger bars with True Nail for easy installation in regular lumber, engineered lumber, and laminated beams. Integral T-bar slots for easy installation in T-bars. Spans up to 24" and can be repositioned 90°. Score lines allow for toll-free hanger bar size reduction. Integral leveling flange allows for single-person installation while easily aligning the housings with the joists.
Junction Box ▪ Junction box with hanger bars and quick-connect for easy fixture installation.
Listing ▪ For 2-Hour Fire Rated Ceilings ▪ IC Airtight Rated for Direct Contact with Insulation ▪ UL Listed under UL 514A Standards as a metallic outlet box
|
|
 |
 |
 |
 |

|