ELCO EL1499-75A

ELCO EL1499-75A - 4" Low Voltage Airtight Universal Housing - 75W Max. - 120V - Magnetic Transformer - LED/MR16 GU/GX5.3 Bi-Pin - Silver/Black

$47.55
Skip to product information

ELCO EL1499-75A - 4" Low Voltage Airtight Universal Housing - 75W Max. - 120V - Magnetic Transformer - LED/MR16 GU/GX5.3 Bi-Pin - Silver/Black

Low stock
Part Number:  EL1499-75A
$47.55

EVERYDAY LOWEST PRICE REGARDLESS OF QUANTITY!

Verified Reviews

Free Shipping Over $500

Secure Checkout

PAYMENT OPTIONS

Payment methods
PayPal Visa Mastercard Discover

MORE ABOUT THIS ITEM

DESCRIPTION
Part Number: EL1499-75A

Compatible With: ELCO 4" MR16 Trims. Sold Separately!

Wattage - 75w Max.
Input Voltage - 120v
Output Voltage - 12V
Bulb Type - 12V/MR16 GU/GX5.3 bi-pin/LED/Halogen (Not Included)
Magnetic Transformer
Dimming - MLV Type

Height - 6 1/2"
Length - 8"
Width - 5 1/4"

  • Single Wall New Construction
  • Housing adjusts in frame to accommodate up to 1 1/4" ceiling thickness
  • Use only dimmers specifically designed for magnetic low voltage transformers
  • Lamp may affect dimmability
  • Lamp Holder: MR16 GU/GX5.3 Bi-Pin Socket
  • Trims and inserts sold separately
  • 3 year factory warranty (limited)
  • UL Listed for Damp Locations/Wet Locations with select trims
  • UL Listed for Feed Through
  • Airtight per ASTM E-283
  • Install a JA8 2016-E Lamp/Luminaire for Title 24 Compliance


<br /><b>Construction/Installation</b><br />▪ Single Wall Airtight New Construction. Low Voltage Airtight Universal Housing.<br />▪ Housing adjusts in frame to accommodate up to 1 1/4" ceiling thickness. Suitable for T-grid and drop ceiling applications.<br />▪ Airtight housing with gasket to restrict airflow in accordance with ASTM E-283 air-tight requirements.<br />▪ Designed for ceiling plenums where 2x8 joists or taller are used. Steel housing for greater heat dissipation. Stamped Galvanized steel frame.<br /><br /><b>Junction Box </b><br />▪ Positioned to accommodate straight conduit runs.<br />▪ Seven (7) 1/2" trade size conduit knockouts, Four (4) 3/4" knockouts with pry-out knockout slots.<br />▪ Four (4) Romex pry-outs with strain relief. See installation sheet for detailed information<br /><br /><b>Hanger Bars / New Construction</b><br />▪ Pre-installed hanger bars with True Nail facilitate easy installation in regular lumber, engineered lumber, and laminated beams. Maximum hole cut-out is 4 1/4".<br />▪ Integral T-bar slots for easy installation in T-bars. Spans up to 24" and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while aligning the housing with joists.<br /><br /><b>Electrical</b><br />▪ Input Voltage: 120VAC. Output Voltage: 12V AC. Max Wattage: 75W. Thermally protected against improper lamping.<br /><br /><b>Dimmability</b><br />▪ Based on lamp selection. Magnetic Transformer dims with MLV type dimmers. Lamp may affect dimmability.<br /><br /><b>Compatible Trims<br /></b>▪ Compatible with - ELCO 4" MR16 Trims and designed for use with 12V MR16 75W Max GU/GX5.3 MR16 LED/Halogen Bulbs: Sold Separately!<br /><br /><b>Listing</b><br />▪ UL Listed for Damp Locations. UL Listed Wet Location with select trims<br />▪ Airtight per ASTM E-283, UL Listed For Feed Through<br />▪ Install a JA8 2016-E Lamp/Luminaire For Title 24 Compliance<br /><br />

TECHNICAL SPECIFICATIONS

<table class="tech_specs_table_wrapper" cellspacing="0" width="100%">
<tbody>
<tr>
<td>
<table class="tech_specs_table" cellspacing="0" width="100%">
<tbody>
<tr>
<th colspan="2" align="left" bgcolor="#f0f0f0">
Tech Specs
</th>
</tr>
<tr>
</tr>
<tr bgcolor="#fefefe">
<td>
</td>
<td>
</td>
</tr>
<tr bgcolor="#f0f0f0">
<td width="28%">Material</td>
<td width="72%">Steel Housing/Stamped Galvanized Steel Frame</td>
</tr>
<tr bgcolor="#fefefe">
<td>
Construction Type
</td>
<td>
Airtight-New Construction-Low Voltage-Universal</td>
</tr>
<tr bgcolor="#f0f0f0">
<td>Hanger Bars</td>
<td>
Spans Up To 24" And Can Be Repositioned 90°<br />
</td>
</tr>
<tr bgcolor="#fefefe">
<td>Voltage</td>
<td>120V</td>
</tr>
<tr bgcolor="#f0f0f0">
<td>
Warranty
</td>
<td>3 Year Factory Warranty (limited)
</td>
</tr>
<tr bgcolor="#fefefe">
<td>
Knockouts
</td>
<td>Seven (7) 1/2" Trade Size Conduit Knockouts, Four (4) 3/4" Knockouts With Pry-Out Knockout Slots, Four (4) Romex Pry-Outs With Strain Relief</td>
</tr>
<tr bgcolor="#f0f0f0">
<td>
Approval Type
</td>
<td>UL - Damp Locations, UL - Wet location (with Select Trims), UL - Feed Through wiring, Airtight Per ASTM E-283, Install A JA8 2016-E Lamp/Luminaire For Title 24 Compliance</td>
</tr>
<tr bgcolor="#fefefe">
<td>
Recessed Size
</td>
<td>4"
</td>
</tr>
<tr bgcolor="#f0f0f0">
<td>
Wattage
</td>
<td>75 Watt Max.</td>
</tr>
<tr bgcolor="#fefefe">
<td>Bulb Type</td>
<td>12V/MR16 GU/GX5.3 Bi-Pin/LED/Halogen (Not Included)</td>
</tr>
<tr bgcolor="#f0f0f0">
<td>Transformer</td>
<td>Magnetic</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>

SHIPPING

Estimated Ground Shipment Times

Orders must be placed by 3pm PST for same-day shipping

REVIEWS

YOU MAY ALSO LIKE

WHY CHOOSE US

Decades of expertise

Comprehensive product range

Committed to efficiency

Quality you trust

Customer-first service